How to Keep Your Screening Equipment in Tip Top Shape

   |   By  |  0 Comments

screening equipment

The headworks screening equipment is the first line of defense for any wastewater facility. Their proper operation is crucial to protect all of the sensitive treatment processes that lie within the fence line. Unfortunately, like all equipment, they do not take care of themselves. We spoke with Brian Prunty, JWC’s Field Service Manager from the Service Solutions group, about what items a plant’s operations staff should consider for the upkeep of their headworks screening equipment.

Q. What is the number one item that causes problems with screening equipment?

By far the most critical item in any in-channel screen is the primary chain. Chains will naturally stretch over time and this is the killer of many screens. If left unchecked, the chain will stretch to the point where an expensive catastrophic failure will occur. A little preventative maintenance can head off this type of failure.

Q. What should an operations or maintenance staff be looking for in chain stretch?

There are a few tell-tale visual signs of the chain stretching. One is that the rollers can get oblong as the chain extends. Also, the outside of the chain can get shiny spots indicating that the chain links are scraping on the bottom of the channel. Additionally, operators should be looking for rollers that are flattening out over time.  Some of this can be corrected by simply tensioning the chain but if there is no adjustment left in the tensioning or the chain is at the end of its useful life, then it needs to be replaced.

Q. What are some other maintenance items to be looking at?

For bar-type screens like JWC’s Chain & Rake Monster, operators will want to make sure that the scraper arm is making good contact with the rakes and removing the solids. Additionally, you should make sure that the rake teeth are in good condition and not retaining excessive debris.

For finescreens it is important to look at the brush systems and spray wash used to remove debris from the screening panels. Brushes will wear over time and spray Screening Equipmentnozzles can get plugged. It is also not uncommon for the plant water supply pressure to change and the spray nozzles may not be removing as much as they were when the screen was installed. If the solids removals elements are not working correctly then carryover of solids can be an issue.

A nice feature that JWC now has available on its Finescreen Monster is a brushless design. By combining our UHMW panels with a dual spray wash system we have been able to eliminate the need for a cleaning brush – and therefore eliminating one maintenance item.

Q.Who do you use to do a major overhaul on a screen?

There are certainly many schools of thought on this. Some plants will want to take it on themselves which I think is great if the staff has the time and the training to do so. This work is obviously not warranted by the screen manufacturer.

A few screen manufacturers have the capability to overhaul screens in various manners. Some companies will require the screen to be removed from the channel and shipped back to the factory for a rebuild which is a pretty costly endeavor.

At JWC our Service Solutions group has the skills and ability to rebuild the screens on-site. A typical rebuild from JWC would include new chain, new bearings, new chain supports, replacement brushes, new seals and other wear items. We basically bring it back to a like-new condition and provide a new 1-year manufacturer’s warranty. Our customers have found this to be a very economical solution to significantly extend the life of their headworks screens.

Wastewater Screening Design for Your Wastewater Plant

   |   By  |  0 Comments

Quick Reference Screening Equipment Guide, Wastewater Screening Design

Wastewater Screening Design Quick Reference Guide

Is your wastewater screening design struggling to meet industry standards? Are you experiencing clogged and damaged equipment on a monthly or even weekly basis? For starters, you should evaluate your preliminary treatment and identify the most effective wastewater screening design for your wastewater plant.

Your screening equipment plays a huge role in your wastewater system as it is the first line of defense to the filtration process. When removing objects such as rags, paper, plastics and metals, screening equipment prevents damage and clogging of downstream equipment.

Screening Equipment, wastewater screening designThe first step to replacing equipment will include distinguishing the correct metrics for your concentrations, conversions, head drops and screen sizes. To assist you in sizing and fitting your next wastewater screening design, JWC has created a Quick Reference to help you measure and convert your specs for screens and components. The different equipment calculations in our new quick reference guide include all of the specs necessary for installation. This user-friendly quick reference guide will help you to convert screen specs precisely in seconds!

Now that you have calculated the necessary specs, you will need to figure out the appropriate screen for your plant. JWC’s goal is to help you to treat your wastewater efficiently and effectively. JWC has carefully engineered wastewater screening systems for a number of applications that include drum, in-channel, auger and static screens for municipal and industrial placements. With so many choices, what wastewater screening system should you use? Let us break it down for you:

  • Rotary Drum Screens are installed in applications that contain flume waters, effluents containing moderate to low solid loadings, high flows or high solids loading zone. These screens are versatile and provide superior solids recovery from waste streams. JWC offers both internally fed drum screens and externally fed drum screens.
  • In-Channel Screens are used in situations without a grinder, usually where there is a limited number of rags and no large solids in the waste stream. JWC offers bar screens, chain and rake screens, fine screens and band screens.
  • Auger Screens are a robust headworks solution that combines three of JWC’s finest technologies – a grinder, a fine screen and a compactor into one unit called the Auger Monster. This spiral screen removes trash and unwanted solids so the treatment plant runs more efficiently.
  • Statics Screens are typically used when the solids are easily separated from the liquid and where the separated solids slide easily. JWC offers Sidehill Static and Sidehill Pressure Screens.

At JWC we offer a wide range of products that target unique challenges with wastewater treatment plants being a top priority.  Drum screens, in-channel screens, auger screens and static screens are all used in municipal and industrial applications. The steps are simple, calculate your specs and choose your screen!

Get your Quick Reference Guide now! Click HERE to download.

Wastewater Screening Made Easy

U.S. MESHINCHESMICRONSMM
0.236260006
50.15740004
0.118130003
100.078720002
120.066116801.68
0.059115001.5
140.055514101.41
160.046911901.19
180.039410001
200.03318410.84
250.0287070.71
300.02325950.59
350.01975000.5
400.01654200.42
450.01383540.35
500.01172970.297
600.00982500.25
700.00832100.21
800.0071770.177
1000.00591490.149
1200.00491250.125
1400.00411050.105
1700.0035880.088
2000.0029740.074
2300.0024630.062
2700.0021530.053
3250.0017440.044
4000.0015370.037
5500.0009250.025